APsystems EZ1-LV plug-in microinverter
For people building their own kit around panels they already have. Component certification is not system certification.
Specs and price checked Nov 20, 2026 Not tested by us
A 900 W plug-in microinverter for two panels, $325, with a standard plug on a 5-meter cord. APsystems says CSA certified it to UL 3700 and that it meets UL 1741 SB. It's the inverter inside US Solar Supplier's kit and Zendure's.
Who it's for
People assembling their own setup around panels they already own. Building your own also means you're responsible for matching panels to the inverter's input limits and mounting everything safely.
Component isn't system
A certified inverter is the most important part, but it doesn't make your homemade kit system-certified. Maine, Vermont, California and New Jersey name system-level standards. APsystems itself says legality depends on your jurisdiction. Optional zero-export comes from its APmeter, sold separately.
Specs
- Type
- Inverter
- Price
- $325
- Panel
- Not included
- Inverter output
- 900 W
- Battery
- None
- Export
- Plug-in grid-tie; optional zero-export meter
- Certification
- CSA-certified to UL 3700 at the component level; meets UL 1741 SB (per APsystems).
- Mounting
- n/a
- Warranty
- 12 years
- Plug
- Standard plug via 5 m cord
- Where sold
- Maker says legality depends on your jurisdiction
Against each state's law
How the product's size and certification line up with the states that have plug-in laws. This compares published specs to the law's text; it isn't legal advice.
| State | Against the law's text | Notes |
|---|---|---|
| California | Needs system certification this product doesn't claim | law starts Jan 1, 2027 |
| Colorado | Fits the law's limits | over 391 W: dedicated circuit or electrician expected |
| Connecticut | Fits the law's limits | — |
| Maine | Needs system certification this product doesn't claim | over 420 W: dedicated circuit or electrician expected |
| Maryland | Fits the law's limits | over 391 W: dedicated circuit or electrician expected |
| New Hampshire | Fits the law's limits | law starts Jan 1, 2027 |
| New Jersey | Needs system certification this product doesn't claim | law starts Mar 1, 2027; over 400 W: dedicated circuit or electrician expected |
| Utah | Fits the law's limits | — |
| Vermont | Needs system certification this product doesn't claim | — |
| Virginia | Fits the law's limits | law starts Jan 1, 2027; over 391 W: dedicated circuit or electrician expected |